Share via email
Some fields are missing
Bürkert - Close to you
Office /1
  • Main Office
  • Headquarters
  • Systemhaus
  • Distributor
  • Office
  • Plant
  • Logistic center
bürkert
 

Cookies must be enabled to use this function. Please accept cookie privacy policy first.

272 Hits

Inline

Type 8011
  • Economic integration in pipe systems without any additional piping
  • Magnetic measuring principle
  • Output: transistor output (frequency pulse signal)

Type 8012
  • Economic integration in pipe systems without any additional pipelines
  • Optic or magnetic measuring principle
  • Outputs: 1 analogue output 4...20 mA and/or 1 transistor output (frequency or switch)
  • Outputs configurable (through interface on USB port with PC)

Type 8030
  • Cost-effective integration in pipe systems
  • 3-wire frequency pulse version for direct connection to PLC (PNP and NPN)
  • Simple connection to Bürkert readers in remote versions

Type 8032
  • Indication, monitoring, transmitting and On/Off control in one device
  • Freely adjustable outputs (transistor or relay)
  • Automatic calibration using Teach-In
  • Process value output: 4…20 mA
  • Flow threshold detector

Type 8035
  • Up to PN16, size of measuring tube: DN06 to DN65
  • Display for indication of flow rate and volume with two totalizers or dosing
  • Automatic calibration using Teach-In
  • Inputs (with batch controller) and all outputs can be checked without the need for actual flow
  • Total and day counters for batch quantity and number of dosing, volume or mass counter indicator (with batch controller)

Type 8036
  • Size of measurement pipes: DN06 to DN65
  • Configurable outputs: one or two transistor output(s) and one or two 4...20 mA current output(s)
  • Removable backlit display/configuration module for indication of flow rate and volume with two flow totalizers
  • Automatic calibration using Teach-In, all outputs can be checked without the need for actual flow

Type 8039
  • Indication, monitoring, transmitting and On/Off control in one device.
  • Programmable outputs (transistor or relay)

Type S010
  • For connection to a transmitter Type SE10 for flow detection (see data sheet flow switch Type 8010)

Type S012
  • For connection to a transmitter Type SE11 or Type SE12 for flow measurement (see data sheets flow meter Types 8011 and 8012)
  • For installation into all pipes from DN06…DN65 or in customer-specific block systems

Type S030
  • DN06 to DN65
  • Wide range of materials and type of process connections available to ideally fit to the individual applications and process conditions
  • Closed pipe system, sensor inside fitting
  • Quarter-turn technology
  • Transmitter available for Indication, Monitoring, Transmitting, On/Off control, Batch control

Type S039
  • For connection to a transmitter Type SE39 for flow measurement (see data sheet flow meter Type 8039)
  • For installation into all pipes from DN06…DN50

Type SE10
  • Compatible with INLINE sensor-fitting Type S010 with paddle wheel for flow measurement (see data sheet Type 8010)

Type SE11
  • For connection to a fitting Type S012 (see data sheet flow meter Type 8011)

Type SE12
  • For connection to a fitting Type S012 (see data sheet flow meter Type 8012)